DSpace About DSpace Software
 

DSpace Biblioteca Universidad de Talca (v1.5.2) >
Facultad de Ingeniería >
Memorias de pregrado Ingeniería Civil Mecatrónica >

Please use this identifier to cite or link to this item: http://dspace.utalca.cl/handle/1950/10484

Title: Estudio de la operación y eficiencia de un DSTATCOM multinivel asimétrico
Authors: Suarez Miño, José Eguis
Muñoz Vidal, Javier (Prof. Guía)
Issue Date: 2014
Publisher: Universidad de Talca (Chile). Escuela de Ingeniería en Mecatrónica
Abstract: En este trabajo se estudia la operación de un DSTATCOM (por sus siglas en ingles Distribution STATic COMpensator), el cual está enfocado en el mejoramiento de la calidad de la energía eléctrica, por medio de la compensación de armónicos y de potencia reactiva. Durante el desarrollo de esta memoria se consideran dos modelos para el filtro activo de potencia, conformado por puentes H en cascada (Cascaded H Bridge). El primero de estos sistemas consiste en un modelo simétrico, en donde todas las celdas tienen la característica de funcionar con el mismo voltaje DC y operar a la misma frecuencia de conmutación.Para el segundo sistema se considera un modelo asimétrico, el cual se caracteriza por trabajar con dos grupos de celdas. Unas celdas se encargan de la compensación de armónicos de corriente (celda de armónicos), la cual funciona a menor voltaje DC y a una mayor frecuencia de conmutación. La segunda celda tienen como función la compensación de potencia reactiva (celda fundamental), funcionando a mayor voltaje DC y a una menor frecuencia de conmutación. En este modelo asimétrico además se pueden implementar estrategias de control independientes, debido a que las componentes de las celdas fundamentales son ortogonales con las componentes de las armónicas.Cabe destacar que para el estudio del sistema DSTATCOM, se realiza el respectivo modelamiento matemático, desarrollando así; el modelo dinámico, el modelo estático y punto de operación para la linealización del sistema, y el posterior diseño de los controladores. También se realizan las simulaciones de los modelos (simétrico y asimétrico), con el fin de realizar un análisis de pérdidas por conmutación, para esto se propone comparar las pérdidas en términos de energía, del modelo asimétrico respecto del simétrico, para determinar cuál es la mejor alternativa, de acuerdo a las condiciones de operación. Los resultados obtenidos de esta investigación, es que los dos modelos analizados, logran los objetivos de compensación de armónicos y el mejoramiento del factor de potencia. Y por último que el modelo asimétrico presenta menores pérdidas asociados al proceso de conmutacion./ ABSTRACT: In this work the operation of a DSTATCOM is studied (by its acronym in english Distribution STATic COMpensator), which is focused in improving the power quality of electrical energy, through the compensation of harmonics and reactive power. During the development of this work two models were considered for the active power filter, formed by Cascaded H-Bridges. The first of these systems is a symmetric model, where all cells have the characteristic of operating with the same DC voltage and operate at the same switching frequency. For the second system it is considered an asymmetric model, which is characterized by working with two groups of cells. Some cells are responsible of the compensation of harmonics currents (harmonic cells), which operates with lower DC voltage and higher switching frequency. The second cells have the function of reactive power compensation (fundamental cells), functioning with higher DC voltage and lower switching frequency. In this asymmetric model, independent control strategies can be implemented, because the fundamental cells components are orthogonal with the components of the harmonics.It is worthy to note, for the study of DSTATCOM system, the respective mathematical modeling is tained, developing thus; the dynamic and static, and the operating point for the linearisation of the system, and the subsequent design of controllers. The models are simulated (symmetric and asymmetric), in order to perform an analysis of the switching losses, this is proposed to compare the losses in terms of energy, the asymmetric model with respect to the symmetric model, to determine what is the best alternative, according to specific operating conditions. The results of this investigation, is that the two models analyzed, achieve the goals of harmonic compensation and power factor improvement. Finally the asymmetric model shows lower losses associated with the switching process.
Description: 112 p.
URI: http://dspace.utalca.cl/handle/1950/10484
Appears in Collections:Memorias de pregrado Ingeniería Civil Mecatrónica

Files in This Item:

File Description SizeFormat
suarez_nino.pdfTabla de Contenido159.24 kBAdobe PDFView/Open
suarez_nino.pdfResumen20.58 kBAdobe PDFView/Open
suarez_nino.htmlLink a Texto Completo3.56 kBHTMLView/Open

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

 

Valid XHTML 1.0! DSpace Software Copyright © 2002-2009  The DSpace Foundation - Feedback